Electronic Control Cables
ScreenedMulti-pair
These paired control cables are suitable for RS422/485 commonly used for data communication purpose. Examples are for Card Access Systems, PLC control, etc. It is also suitable for voice signal like in the case of microphone application.
Typical
Construction of UL2464 Style Screened Control Cables:
|
|
Conductor Size |
16 AWG |
18 AWG |
20 AWG |
22 AWG |
|
Conductor |
Material |
Stranded Tinned Copper |
Stranded Tinned Copper |
Stranded Tinned Copper |
Stranded Tinned Copper |
|
Composition (No/mm) |
26/0.254 |
17/0.254 |
21/0.18 |
17/0.16 |
|
|
Insulation |
Material |
PVC |
PVC |
PVC |
PVC |
|
Diameter (mm) |
2.7 +/- 0.1 |
2.1 +/- 0.1 |
1.6 +/- 0.1 |
1.3 +/- 0.1 |
|
|
Screen |
Material |
Aluminum/ Polyester Tape |
Aluminum/ Polyester Tape |
Aluminum/ Polyester Tape |
Aluminum/ Polyester Tape |
|
Drain
Wire |
Material |
Stranded Tinned Copper |
Stranded Tinned Copper |
Stranded Tinned Copper |
Stranded Tinned Copper |
|||
|
Composition (No/mm) |
7/0.32 |
7/0.32 |
7/0.254 |
7/0.254 |
||||
|
Construction |
No. of Pairs |
1 |
1 & 2 |
1, 2, 3, 4, 6 & 8 |
1, 2, 3, 4 & 6 |
|||
|
Outer Sheath |
Material |
PVC |
PVC |
PVC |
PVC |
|||
|
Diameter
(mm) |
6.00
+/- 0.15 |
1 pr |
5.60 +/- 0.15 |
1 pr |
5.20 +/- 0.15 |
1 pr |
5.00 +/- 0.15 |
|
|
2 pr |
7.00 +/- 0.15 |
2 pr |
6.00 +/- 0.15 |
2 pr |
6.00 +/- 0.15 |
|||
|
|
3 pr |
7.20 +/- 0.15 |
3 pr |
6.40 +/- 0.15 |
||||
|
4 pr |
8.00 +/- 0.20 |
4 pr |
7.00 +/- 0.15 |
|||||
|
6 pr |
9.50 +/- 0.20 |
6 pr |
8.10 +/- 0.20 |
|||||
|
8 pr |
10.60 +/- 0.30 |
8 pr |
9.00 +/- 0.30 |
|||||
Multi-core (RS232, Signal)
These non-twisted cables are normally used in data communication that does not require twisting and for short distance, eg. RS232.
Typical Construction of UL2464 Style Screened Control Cables:
|
|
Conductor Size |
16 AWG |
18 AWG |
22 AWG |
24 AWG |
|||
|
Conductor |
Material |
Stranded Tinned Copper |
Stranded Tinned Copper |
Stranded Tinned Copper |
Stranded Tinned Copper |
|||
|
Composition (No/mm) |
26/0.254 |
17/0.254 |
17/0.16 |
17/0.16 |
||||
|
Insulation |
Material |
PVC |
PVC |
PVC |
PVC |
|||
|
Diameter (mm) |
2.7 +/- 0.1 |
2.1 +/- 0.1 |
1.3 +/- 0.1 |
1.3 +/- 0.1 |
||||
|
Screen |
Material |
Aluminum/ Polyester Tape |
Aluminum/ Polyester Tape |
Aluminum/ Polyester Tape |
Aluminum/ Polyester Tape |
|||
|
Drain Wire |
Material |
Stranded Tinned Copper |
Stranded Tinned Copper |
Stranded Tinned Copper |
Stranded Tinned Copper |
|||
|
Composition (No/mm) |
7/0.254 |
7/0.254 |
7/0.254 |
7/0.254 |
||||
|
Construction |
No. of Cores |
4 |
3 & 4 |
3, 4, 6 & 8 |
4, 6, 10 & 12 |
|||
|
Outer Sheath |
Material |
PVC |
PVC |
PVC |
PVC |
|||
|
Diameter (mm) |
9.00 +/- 0.20 |
3 c |
5.60 +/- 0.15 |
3 c |
4.60 +/- 0.15 |
4 c |
4.40 +/- 0.15 |
|
|
4 c |
6.30 +/- 0.15 |
4 c |
6.00 +/- 0.15 |
6 c |
5.10 +/- 0.15 |
|||
|
|
6 c |
7.20 +/- 0.15 |
10 c |
6.00 +/- 0.15 |
||||
|
8 c |
8.00 +/- 0.20 |
12 c |
6.50 +/- 0.15 |
|||||
Aluminium foil screened/ Braiding
Such cables are normally used in security systems that require better screening and at the same time provide some form of protection.
VGA
This UL2919 standard cable comes with 3 mini coaxial cable and 6 cores 24AWG control, normally used for projectors.
Special (LSOH, Armouring)
The above cables are available with special jacket (PE, LSOH) and steel wire braiding or steel wire armor on request.